LCR¹ÌÅÍ, 100Hz~200KHz LCR Meter, 6372
ÆÇ¸Å°¡°Ý 4,070,000¿ø
ºê·£µå MICROTEST
Á¦Á¶»ç MICROTEST
Á¦Ç°ÄÚµå 6372
ÁÖ¹®¼ö·®
»ó¼¼¼³¸í »óǰÈıâ(0) »óǰ¹®ÀÇ(0) ±³È¯ ¹× ¹Ýǰ/¹è¼Û/°áÁ¦



 

Ư ¡


¢º Basic accuracy up to 0.1%
¢º LCR Meters are all compatible with convenient and efficient Meter Link Software
¢º Overall Compact design, good for production line use
¢º User-friendly interface, allows for production line personnel to operate efficiently


»ç ¾ç


Measurement Data

Test Frequency 100Hz-200KHz
Points Of Test Frequency 390 steps
Basic Accuracy

¡¾ 0.1%

AC Drive Level

0.05V¡¢0.1V¡¢0.25V¡¢0.5V¡¢1V

DC Drive Level

0.5V
Output Impedance 100¥Ø

Frequency trimming resolution

10 Digits

Frequency output accuracy

¡¾ 0.01%

AC test speed (Fast) 5 times/sec
AC test speed (Medium) 3 times/sec
AC test speed (Slow) 2 times/sec
DC test speed (Fast) 5 times/sec
DC test speed (Medium) 3 times/sec
DC test speed (Slow) 2 times/sec
Bias voltage 2V

Specifications

ESR Series/Parallel
Mathematical Mode Absolute/Percentage
Test Range Automatic/Lock
Indicator Pass/Fail/Bias LED and Built-in speaker

Output Terminal

BNC connector

Safety EN61010-1
Immunity EN61326-1
Emissions EN55022 Class A

Calibration

Open Circuit / Short Circuit: Avoid the misreading caused by the stray capacitance from kelvin clips and fixtures

Power Supply

Voltage 90-132Vac or 198-264Vac (selectable)

Frequency 47-63Hz

LED Display

240*64 dot-matrix display

Interface RS-232, GPIB (option), Handler (option)
Flash Memory

Storage of 127 rewritable data sets

Operation Auto¡¢Manual¡¢Remote Control¡¢RS-232¡¢GPIB (option)
Environment Temperature : 10¡ÆC to 40¡ÆC Humidity : 20 ~ 90%
Dimension (W*H*D) 340x88x330 mm
Weight 5 Kg

Parameters Measurement Ranges

£üZ£ü R X 0.1 m¥Ø - 100M¥Ø
£üY£ü G B 10nS - 1000S
Cs Cp 0.01pF - >1F
Ls Lp 0.01nH - 100KH
D 0.00001 - 9.9999
Q 0.1 - 9999.9
DCR 0.1m¥Ø - 100M¥Ø
¥Ä% -999.99% - 999.99%
¥È -180¡Æ - +180¡Æ



Application Note


Resistance, Capacitance, Inductance, Oscillators, Sensors, Delay Line, Filters, Resonators



¿É ¼Ç


¢º Standard Accessories
- Power cord
- User manual
- BNC Kelvin Clips (F423501)

¢º Optional Accessories
- Meter Link
- SoftwareRS-232
- CableHandler Box
- F423502
- F423504
¹«´Ü¼öÁý¹× º¹À縦 ±ÝÇÕ´Ï´Ù .
»óǰÁ¤º¸°í½Ã
Á¦Ç°¸í LCR¹ÌÅÍ, 100Hz~200KHz LCR Meter, 6372
ÆÇ¸Å°¡°Ý 4,070,000¿ø
ºê·£µå MICROTEST
Á¦Á¶»ç MICROTEST
°ü·Ã»óǰ
À§ »óǰ°ú °ü·ÃµÈ »óǰÀÌ ¾ø½À´Ï´Ù.
»ó¼¼¼³¸í »óǰÈıâ(0) »óǰ¹®ÀÇ(0) ±³È¯ ¹× ¹Ýǰ/¹è¼Û/°áÁ¦
¹øÈ£ Á¦¸ñ À̸§ º°Á¡ ³¯Â¥
¾ÆÁ÷ ÀÛ¼ºµÈ »óǰÆòÀÌ ¾ø½À´Ï´Ù.
 
»ó¼¼¼³¸í »óǰÈıâ(0) »óǰ¹®ÀÇ(0) ±³È¯ ¹× ¹Ýǰ/¹è¼Û/°áÁ¦
¹øÈ£ Á¦¸ñ À̸§ ³¯Â¥
ÀÛ¼ºµÈ »óǰ¹®Àǰ¡ ¾ø½À´Ï´Ù.
  »óǰ¹®ÀÇÇϱâ
»ó¼¼¼³¸í »óǰÈıâ(0) »óǰ¹®ÀÇ(0) ±³È¯ ¹× ¹Ýǰ/¹è¼Û/°áÁ¦
¹Ýǰ±³È¯
±¸ÀÔÁ¦Ç°ÀÇ ÀÌ»óÀÌ ÀÖÀ» °æ¿ì
- ±¸ÀÔÈÄ 7ÀÏ À̳»¿¡ µ¿ÀÏÁ¦Ç°À¸·Î ±³È¯ °¡´ÉÇÏ¸ç ¿î¼Ûºñ´Â ÆÇ¸ÅÀÚ ºÎ´ãÀÔ´Ï´Ù.
- ´Ù¸¥ Á¦Ç°À¸·Î ±³È¯, ¶Ç´Â ÀÌ»óÀÌ ¾ø´Â Á¦Ç°°ú ÇÔ²² ±³È¯À» ¿øÇÏ½Ç °æ¿ì ±¸¸ÅÀÚ²²¼­ ¿î¼Ûºñ¸¦ ºÎ´ãÇÕ´Ï´Ù.

±¸ÀÔÁ¦Ç°ÀÇ ÀÌ»óÀÌ ÀÖÀ» °æ¿ì (»ö»ó,»çÀÌÁî,´Ù¸¥»óǰ±³È¯)
- ±¸ÀÔÈÄ 7ÀÏÀ̳» ±³È¯ °¡´ÉÇÏ¸ç ±¸¸ÅÀÚ²²¼­ ¿î¼Ûºñ¸¦ ºÎ´ãÇÕ´Ï´Ù.

!! ÁÖÀÇ»çÇ×
ºñ´ÒÆ÷Àå ¹× TagÀÇ Æó±â ¶Ç´Â ÈÑ¼Õ µîÀ¸·Î »óǰ °¡Ä¡°¡ ¸ê½ÇµÈ °æ¿ì¿¡´Â Á¦ÇÑ.
¹Ýǰ½Ã¿¡ ÇØ´ç »çÀºÇ°ÀÌ ÀÖÀ» °æ¿ì °°ÀÌ º¸³»ÁÖ¼Å¾ß ÇÕ´Ï´Ù.
¹è¼Û¾È³»
°áÁ¦ÈÄ 3~7ÀÏ À̳»¿¡ »óǰÀ» ¹Þ¾Æ º¸½Ç ¼ö ÀÖ½À´Ï´Ù.
±¹³» ÃÖ´ëÀÇ ¹°·ù»ç ¿»·Î¿ìĸÅù踦 ÅëÇÏ¿© ½Å¼ÓÇÏ°í ¾ÈÀüÇÏ°Ô ¹è¼ÛµË´Ï´Ù.
¸ðµç Á¦Ç°Àº ÂøºÒ ¹ß¼ÛµË´Ï´Ù. ´Ü 30¸¸¿ø ÀÌ»ó ±¸ÀԽà ¹«·á¹è¼ÛÀÔ´Ï´Ù.
(Á¦ÁÖµµ¸¦ Æ÷ÇÔÇÑ µµ¼­,»ê°£Áö¿ªÀº Ç×°ø·á ¶Ç´Â µµ¼±·á°¡ Ãß°¡µË´Ï´Ù.)
°áÁ¦¾È³»
°áÁ¦¹æ¹ýÀº ½Å¿ëÄ«µå, ±¹¹Î/BC(ISP), ¹«ÅëÀåÀÔ±Ý, Àû¸³±ÝÀÌ ÀÖ½À´Ï´Ù.
Á¤»óÀûÀÌÁö ¸øÇÑ °áÁ¦·Î ÀÎÇÑ ÁÖ¹®À¸·Î ÆÇ´ÜµÉ ¶§´Â ÀÓÀÇ·Î ¹è¼ÛÀÌ º¸·ùµÇ°Å³ª,ÁÖ¹®ÀÌ Ãë¼ÒµÉ ¼ö ÀÖ½À´Ï´Ù.
»óÈ£ : ¿¡À̺ñÅ¥(ABQ)»ê¾÷     ÁÖ¼Ò : ÀÎõ±¤¿ª½Ã °è¾ç±¸ ÁÖºÎÅä·Î413¹ø±æ32     ´ëÇ¥ÀÚ : ÇãÁ¾¼ø     »ç¾÷ÀÚµî·Ï¹øÈ£ : 573-06-02527 (Á¤º¸È®ÀÎ)
Åë½ÅÆÇ¸Å¾÷½Å°í : 2015-ÀÎõ°è¾ç-0634È£     °³ÀÎÁ¤º¸°ü¸®Ã¥ÀÓÀÚ : ±èÈñÁ¤     °³ÀÎÁ¤º¸º¸È£±â°£ : ȸ¿øÅ»Åð½Ã