X-ma 6100/6300/6100S (Double beam) , ºÐ±¤ ±¤µµ°è ,190 ~ 1100 nm ,Nano-¥ì Photometer
190 ~ 1100 nm
ÆÇ¸Å°¡°Ý °¡°Ý¹®ÀÇ
¿ø»êÁö oem
Á¦Ç°ÄÚµå Nano-¥ì Photometer
»ó¼¼¼³¸í »óǰÈıâ(0) »óǰ¹®ÀÇ(0) ±³È¯ ¹× ¹Ýǰ/¹è¼Û/°áÁ¦




Specifications

 

X-ma 6100 (PC)

X-ma 6300(PC)

X-ma 6100S(PCS)

Performance

Wavelength Range

190 ~ 1100 nm

a. Basic ModeAbesorbance. Transmitiance or Concentration measurementsb. Quantitartive Esrablish or use Stored calbration to measure the concentration of unknownsc. WL scanSpectrum scan of sample at any selected wavelenght range with choice of scanning speed and wavelength intervald. KineticsMeasurement of absorbance changing vs. time with reaction rate calculation functione.Multi WavelengthMesasurement at multiple wavelengths to analyze and determine the composition of the mixturesf. DNA/proteinCalculation if concentration and DNA purity. Ratio at other wavelengths can be measured

Spectral Bandwidth

1.8 nm

1.0 nm

0.5/1/2/4nm

Optical System

Double beam, Grating 1200 lines/mm

Wavelength Accuracy

¡¾0.3nm

¡¾0.3nm

¡¾0.3nm

Wavelength Repeatability

0.2nm

0.2nm

0.2nm

Scanning Speed

Hi, Med, Low, Max 3000nm/min

Photometric Accuracy

¡¾ 0.3%T

¡¾ 0.3%T

¡¾ 0.3%T

Photometric Repeatability

¡¾ 0.15%T

¡¾ 0.15%T

¡¾ 0.15%T

Photometric Range

-0.3 to 3.0A , 0 to 200%T, 0 to 9999Conc.

Stray Light

¡¾ 0.05%T

Stability

¡¾0.001A/h

¡¾0.001A/h

¡¾0.001A/h

Display

LCD(100x78mm) or PC Model

Baseline Flatness

¡¾0.001A

¡¾0.001A

¡¾0.001A

Optional Accessories

Sample Compartment

-Auto 8 cell holder (STD)

- 3, 5, 10 cm 4-cell holder- Water-jacket cell holder - Micro cell holder - Ambient sipper/ Peltier system - Test tube holder- Printer- Cell

Light Source

Halogen &Deuterium lamp(Pre-Aligned)

Output

USB Port &Parallel Port (Print)

Power Requirement

220/110V, 50/60Hz

Dimensions (WxDxH)

600x450x200mm

Weight

22kg





































































 

¹«´Ü¼öÁý¹× º¹À縦 ±ÝÇÕ´Ï´Ù .
»óǰÁ¤º¸°í½Ã
Á¦Ç°¸í X-ma 6100/6300/6100S (Double beam) , ºÐ±¤ ±¤µµ°è ,190 ~ 1100 nm ,Nano-¥ì Photometer
ÆÇ¸Å°¡°Ý °¡°Ý¹®ÀÇ
¿ø»êÁö oem
°ü·Ã»óǰ
À§ »óǰ°ú °ü·ÃµÈ »óǰÀÌ ¾ø½À´Ï´Ù.
»ó¼¼¼³¸í »óǰÈıâ(0) »óǰ¹®ÀÇ(0) ±³È¯ ¹× ¹Ýǰ/¹è¼Û/°áÁ¦
¹øÈ£ Á¦¸ñ À̸§ º°Á¡ ³¯Â¥
¾ÆÁ÷ ÀÛ¼ºµÈ »óǰÆòÀÌ ¾ø½À´Ï´Ù.
 
»ó¼¼¼³¸í »óǰÈıâ(0) »óǰ¹®ÀÇ(0) ±³È¯ ¹× ¹Ýǰ/¹è¼Û/°áÁ¦
¹øÈ£ Á¦¸ñ À̸§ ³¯Â¥
ÀÛ¼ºµÈ »óǰ¹®Àǰ¡ ¾ø½À´Ï´Ù.
  »óǰ¹®ÀÇÇϱâ
»ó¼¼¼³¸í »óǰÈıâ(0) »óǰ¹®ÀÇ(0) ±³È¯ ¹× ¹Ýǰ/¹è¼Û/°áÁ¦
¹Ýǰ±³È¯
±¸ÀÔÁ¦Ç°ÀÇ ÀÌ»óÀÌ ÀÖÀ» °æ¿ì
- ±¸ÀÔÈÄ 7ÀÏ À̳»¿¡ µ¿ÀÏÁ¦Ç°À¸·Î ±³È¯ °¡´ÉÇÏ¸ç ¿î¼Ûºñ´Â ÆÇ¸ÅÀÚ ºÎ´ãÀÔ´Ï´Ù.
- ´Ù¸¥ Á¦Ç°À¸·Î ±³È¯, ¶Ç´Â ÀÌ»óÀÌ ¾ø´Â Á¦Ç°°ú ÇÔ²² ±³È¯À» ¿øÇÏ½Ç °æ¿ì ±¸¸ÅÀÚ²²¼­ ¿î¼Ûºñ¸¦ ºÎ´ãÇÕ´Ï´Ù.

±¸ÀÔÁ¦Ç°ÀÇ ÀÌ»óÀÌ ÀÖÀ» °æ¿ì (»ö»ó,»çÀÌÁî,´Ù¸¥»óǰ±³È¯)
- ±¸ÀÔÈÄ 7ÀÏÀ̳» ±³È¯ °¡´ÉÇÏ¸ç ±¸¸ÅÀÚ²²¼­ ¿î¼Ûºñ¸¦ ºÎ´ãÇÕ´Ï´Ù.

!! ÁÖÀÇ»çÇ×
ºñ´ÒÆ÷Àå ¹× TagÀÇ Æó±â ¶Ç´Â ÈÑ¼Õ µîÀ¸·Î »óǰ °¡Ä¡°¡ ¸ê½ÇµÈ °æ¿ì¿¡´Â Á¦ÇÑ.
¹Ýǰ½Ã¿¡ ÇØ´ç »çÀºÇ°ÀÌ ÀÖÀ» °æ¿ì °°ÀÌ º¸³»ÁÖ¼Å¾ß ÇÕ´Ï´Ù.
¹è¼Û¾È³»
°áÁ¦ÈÄ 3~7ÀÏ À̳»¿¡ »óǰÀ» ¹Þ¾Æ º¸½Ç ¼ö ÀÖ½À´Ï´Ù.
±¹³» ÃÖ´ëÀÇ ¹°·ù»ç ¿»·Î¿ìĸÅù踦 ÅëÇÏ¿© ½Å¼ÓÇÏ°í ¾ÈÀüÇÏ°Ô ¹è¼ÛµË´Ï´Ù.
¸ðµç Á¦Ç°Àº ÂøºÒ ¹ß¼ÛµË´Ï´Ù. ´Ü 30¸¸¿ø ÀÌ»ó ±¸ÀԽà ¹«·á¹è¼ÛÀÔ´Ï´Ù.
(Á¦ÁÖµµ¸¦ Æ÷ÇÔÇÑ µµ¼­,»ê°£Áö¿ªÀº Ç×°ø·á ¶Ç´Â µµ¼±·á°¡ Ãß°¡µË´Ï´Ù.)
°áÁ¦¾È³»
°áÁ¦¹æ¹ýÀº ½Å¿ëÄ«µå, ±¹¹Î/BC(ISP), ¹«ÅëÀåÀÔ±Ý, Àû¸³±ÝÀÌ ÀÖ½À´Ï´Ù.
Á¤»óÀûÀÌÁö ¸øÇÑ °áÁ¦·Î ÀÎÇÑ ÁÖ¹®À¸·Î ÆÇ´ÜµÉ ¶§´Â ÀÓÀÇ·Î ¹è¼ÛÀÌ º¸·ùµÇ°Å³ª,ÁÖ¹®ÀÌ Ãë¼ÒµÉ ¼ö ÀÖ½À´Ï´Ù.
»óÈ£ : ¿¡À̺ñÅ¥(ABQ)»ê¾÷     ÁÖ¼Ò : ÀÎõ±¤¿ª½Ã °è¾ç±¸ ÁÖºÎÅä·Î413¹ø±æ32     ´ëÇ¥ÀÚ : ÇãÁ¾¼ø     »ç¾÷ÀÚµî·Ï¹øÈ£ : 573-06-02527 (Á¤º¸È®ÀÎ)
Åë½ÅÆÇ¸Å¾÷½Å°í : 2015-ÀÎõ°è¾ç-0634È£     °³ÀÎÁ¤º¸°ü¸®Ã¥ÀÓÀÚ : ±èÈñÁ¤     °³ÀÎÁ¤º¸º¸È£±â°£ : ȸ¿øÅ»Åð½Ã